Digitalization of Building Technology


OAS SBS JACE 8N4 BACnet® Automation platform
The open and high-performance automation and integration platform based on Niagara Framework® N4. For OAS system partners.

SBS IOM (Modbus) I/O Feldbusmodule
The open Modbus I/O system
The OAS-SBS-IOM series consists of compact fieldbus modules with inputs and outputs for DIN rail mounting, on the mounting plate in the control cabinet or electrical distribution board, or in a 19" rack, for door mounting.
Open, compact, convenient
Slim, intelligent and standardized is the series of SBS IOM fieldbus modules from OAS. This consists of compact fieldbus modules with inputs and outputs for analog and digital signals. The fieldbus modules acquire the signals of the building services equipment and pass them on to the controllers. Due to the standardized communication via Modbus, no further gateways are required.
OAS-SBS-IOMR-1025
3- point relay outputs
2x 3-point relay outputs: 2x 3-point DO-/ 4x DI module
Digital output module with 2 x 3-point relay outputs 230 V / 3 A in two groups, for controlling 2 OPEN - STOP - CLOSE drives such as valves, dampers, shutters. Venetian blinds or similar.
LVB realization by means of slide switch. 2 x Auto-Off -Man (manual) switches, 2 x OPEN - STOP - CLOSE - switches.
Parameters such as running times, emergency position, etc. can be conveniently set via the NIAGARA N4-based OAS I/O WEB module configurator. The parameters are also available as exposed Modbus registers.

Tridium JACE 8000® BACnet® Automation platform
The open and high-performance automation and integration platform based on Niagara Framework® N4.

JACE 8000® - I/O Module IO R 34
34 I/O points module (IO-R-34)
16 universal inputs:
- Type-3 temperature sensor (10 K),
- 0-100 kOhm,
- 0-10 V DC,
- 0-20 mA with external resistor
10 relay outputs (A-contacts, 24 V AC at 0.5 A)
8 analog outputs (0-10 V DC)
Learn More

JACE 8000® - I/O Module IO R 16
16 I/O points module (IO-R-16)
8 universal inputs:
- Type-3 temperature sensor (10 K),
- 0-100 kOhm,
- 0-10 V DC,
- 0-20 mA with external resistor
4 relay outputs (A-contacts, 24 V AC at 0.5 A)
4 analog outputs (0-10 V DC)
Learn More

Niagara EDGE 10 BACnet® I/O Controller
IP-based IO controller, based on Niagara Framework N4.
- 5 universal inputs
- 3 digital outputs
- 2 analog outputs
- 1 serial 485 port
- 2 Ethernet ports










![[Translate to Englisch:] OAS-SBS-IOM-1021 [Translate to Englisch:] OAS-SBS-IOM-1021](/fileadmin/bilder/products/sbsiom/sbs_1021_transparent_quadrat.png)
![[Translate to Englisch:] OAS-SBS-IOMR-1022 [Translate to Englisch:] OAS-SBS-IOMR-1022](/fileadmin/bilder/products/sbsiom/sbs_1022_transparent_quadrat.png)
![[Translate to Englisch:] OAS-SBS-IOM-1023 [Translate to Englisch:] OAS-SBS-IOM-1023](/fileadmin/user_upload/sbs_1023_transparent_quadrat2.png)
![[Translate to Englisch:] OAS-SBS-IOMR-1024 [Translate to Englisch:] OAS-SBS-IOMR-1024](/fileadmin/bilder/products/sbsiom/sbs_1024_transparent_quadrat.png)
![[Translate to Englisch:] OAS-SBS-IOMR-1025 [Translate to Englisch:] OAS-SBS-IOMR-1025](/fileadmin/bilder/products/sbsiom/sbs_1025_transparent_quadrat.png)