SBS EDGE XN4 - Technical Data
Tridium’s Niagara Edge 10 is an IP-based field equipment controller powered by the Niagara Framework®. Niagara Edge 10 controllers drive applications such as zone temperature control, and the operation of fan coil units, singlestage air handling units, water-source heat pumps and more
Technical Specifications
Niagara 4 – Requires Niagara 4.7 or later
Specifications
Specifications
- Powered by the Niagara Framework®
- 5 universal inputs
- 3 digital outputs
- 2 analog outputs
- 1 485 serial port
- 2 ethernet ports that support daisy-chain topology
- Expandable via two IO-R-34 modules
- ACE Deterministic runtime engine (*ACE Deterministic runtime engine available in Niagara 4.8)
- 24VAC/DC source
Hardware
Hardware
- NXP iMX6 SoloX2: 800 MHz ARM Cortex-A9/M4
- 512 MB DDR SDRAM
- 2GB total eMMC flash storage with user space set at 1GB
- Powered from 24VAC/DC source
- 5 Universal inputs: Type 3 (10K) thermistors, 0-100K ohm, 0-10VDC, 0-20mA with external resistor, Dry Contact
- 2 Analog outputs: 0-10VDC, 4mA max output current
- 3 Digital outputs: Triac, 24VAC @.5 amp
- 2 10/100MB Ethernet ports capable of daisy chaining
- 1 RS-485 serial port
- Real-time clock
- Secure boot
Expandability
Expandability
Two (2) IO-R-34 or four (4) IO-R16 connected over a shielded 485 bus. IO-R-16 expansion requires a separate power supply for each IOR-16 module.
Connectivity
Connectivity
When data from external sources — i.e. thermostats, variable speed drives, or smart sensors — is required to drive an application, the Niagara Edge 10 allows for connections to those types of external sources using BACNet/ IP, Modbus, and SNMP over an IP network and/or BACnet and Modbus over a 485 network.
Environmental specifications
Environmental specifications
- Operating temperature: -20 to 60°C
- Storage temperature: -40 to 85°C
- Humidity: 5-95% non-condensing
- Shipping & vibration: ASTM D4169, Assurance Level II
- MTBF: 10 years
Agency Certifications
Agency Certifications
- FCC Part 15, class b
- C-UL
- CE
- UL916, Open Energy Management Class 2
- RoHS2
- REACH
- WEEE
- CAN/CSA-C22.2 No. 205-12
Applications
Applications
- Fan coil unit
- Single-stage air handling unit
- Water source heat pump
- Zone control
- Boiler with hot water reset
- And much more…
Mounting
Mounting
Support mounting on EN50022 standard 7.5mm x 35mm DIN rail or panel mounting
SBS EDGE XN4 Key Features
This state-of-the-art controller features a new global design that can be integrated into existing systems and adapted to future challenges.
Niagara Edge device management made easy.
ACE Deterministic Engine
ACE Deterministic Engine
Utilize Wire Sheet to create deterministic applications that enable fast startup to control time and deterministic timing when servicing the IO.
Network
Network
Edge 10 controllers can be daisy chained to continue network connectivity and eliminate the need for separate wiring back to a switch.
Connect Niagara Edge 10 controllers to your main building or IT network and manage them directly with a Supervisor alongside of a JACE®.
Use the secondary Ethernet port of the JACE 8000 to create a private network of Niagara Edge 10 controllers.
Quickly build your network
Quickly build your network
Based on the volume of edge devices at a site, adding devices to your Supervisor may be a challenge. Join edge devices to your network more quickly with tools that ease the process of adding and managing a field of edge devices, which reduces overall installation and configuration time.
Easily manage and deploy updates
Easily manage and deploy updates
Edge devices typically have a single purpose, with multiple devices serving the same function. Use Niagara to create application templates and deploy to multiple devices with specific properties unique to each device.
Keep your network secure
Keep your network secure
Security is always critical but implementing it across numerous devices on a network can be tedious. Tridium has built tools that assist systems integrators in provisioning and managing security settings across devices.
Connectivity
Connectivity
When data from external sources — i.e. thermostats, variable speed drives, or smart sensors — is required to drive an application, the Niagara Edge 10 allows for connections to those types of external sources using BACNet/ IP, Modbus, and SNMP over an IP network and/or BACnet and Modbus over a 485 network.